Download Calibration Software
There are two versions of the calibration program. One for Linux and the other for Windows. Click on the appropriate link for your operating system below:
Linux: baromcal Windows: baromcal.exe
Building The Calibration Fixture
Materials Required - locate the following materials that came with the kit except as noted below.
Qty Description 10' 1/4” O.D., 0.170” I.D. Vinyl tubing 3 fuse clips 3 #6 machine screws (not supplied) 5' 1” x 1/4” flat latice (not supplied)
Assembly
Ok Procedure With a square, draw a perpendicular line across the width of the lattice approximately 3" from one end. Mount two of the fuse clips, equally spaced, on this line. The screws should be attached on the line. The open ends of the clips should align with length of the latice. See the pictorial for details. Measure exactly 40" from the perpendicular line drawn above and draw a second perpendicular line on the latice. Mount the third fuse clip centered on this line. As with the upper clips, the open ends should be alinged with the length of the lattice. If this has been done correctly, you should measure exactly 40" from the top of the top clips to the top of the bottom clip. You may wish to drill a suitably sized hole at the top of the fixture so it can be hung during the calibration procedure.
The Procedure Explained
The first recorded use of the mercury barometer was in 1642 by a gentleman named Torricelli. With this type of barometer, the height of mercury in a glass column closed at the top is connected to a small vessel of mercury that is open to the atmosphere at the bottom. As the atmospheric pressure increases, it pushes down on the mercury in the vessel, forcing it higher in the column. When atmospheric pressure drops, less pressure is exerted on the mercury and the height of the column falls. The measurement has traditionally been made in inches. The calibration method used with this kit is based on this principal, although mercury is not used.
A fact that is little known is that the same principal can be applied to water. Water, however, is considerably lighter than mercury. Therefore the height of the column to apply the same amount of pressure against the atmosphere must also be greater. Knowing this, and the conversion factors between mercury and water densities, we can achieve calibration by varying the height of a column of water and noting the difference in pressure.
The software calibration program will guide you through the steps to get the correct gain and offset for your particular installation. After adjusting an initial offset, the program will prompt you to change the height of one side of the calibration tubes and to adjust the gain potentiometer on the interface board as required. Once the gain has been set, you will then make a final adjustment of the offset which is used to compensate for altitude. The latter adjustment will require access to the current barometric pressure from the nearest NWS office or airport.
Preparing For Calibration
Calibration
During the calibration, you will be instructed to move the tubing in the clip farthest from the
pressure transducer to the lower clip. This picture shows the tubing correctly placed for this
step.

Ok Procedure Connect a DB9 cable from your COM port to the sensor/interface board. Connect power to the sensor/interface board and allow it to run for 30 minutes before proceeding. This is necessary to for all the components to stabilize. At the command prompt, run the calibrate utility.
For Linux, the command is
./calibrate /dev/ttySnwhere n is the serial port you are using. Note the leading dot before the forward slash!
For Windows, entercalibrate COMnwhere n is the COM port you are using.
From this point on, the calibration program will guide you through the steps to calibrate your barometer. The procedure may take up to about 30 minutes, so take your time and be patient. You will be rewarded with an accurate and stable barometer that should serve you well.
Important! If the elevation of the installed board is changed more than a few feet, the Offset setting will need to be adjusted to compensate. Just be careful not to touch the gain setting.
More Information
If you are curious about the math involved with the calibration and use of the barometer, see the Programer's Guide.
Congratulations! You have completed the assembly and initial testing of your 1-Wire® Indoor Sensor and Interface kit. Proceed to the installation.