Preliminary Voltage Checks
1-Wire Indoor Interface/Sensor Kit
In the following, be careful not to short any connection while probing with your multimeter. You
should also be aware that a protection diode is on the power supply input to the board. If reverse
polarity is applied, the diode will conduct, shorting the power supply. Therefore, when you apply
power for the first time in the next step, check the voltage very quickly to be sure you get a
reading. If not, immediately remove power and find the cause before continuing.
|
Ok
|
Procedure
|
|
|
Connect the DC power source to the power jack and measure the voltage across D4 with
the positive lead to the cathode (banded end) and the negative to the anode. You should
read a voltage in the range of 14-18 VDC. If not, immediately disconnect the power and
find the problem before continuing with the next step.
|
|
|
With the negative meter lead connected to the anode of D4 (same as above), +12V should
be read at the ‘+12’ position at P19.
|
|
|
In like manner, with the negative meter lead still connected to the anode of D4, +5V should
be read at the ‘RG’ position at P1.
|
Again, if you fail to get any of the above readings, you must find and fix the problem before
proceeding.
Next